MIL-I-60513A
Critical |
||
1 |
Mixed initiators |
Visual |
2 |
Initiator pin not in cocked position |
Visual |
3 |
Safety pin missing or improperly engaged |
Visual |
Major
1010-ring missing or not lubricated Visual
102Thread damagVeidsual
103Burr Visual
104Foreign matter Visual
Minor
None defined
4.2.2.3 Assembly, Drawing 8596101, less Drawing 8593314 and MIL-C-5501/11.
Critical |
||
1 |
Cartridge loose |
Manual/Visual |
2 |
Cartridge retainer loose |
Manual/Visual |
3 |
Metering groove of cartridge retainer missing |
Visual |
4 |
Elongated hole of cartridge retainer missing |
Visual |
Major
101Burr Visual
102Foreign matter Visual
Minor
None defined
4.2.2.4 Assembly, Drawing 8596101, less MIL-C-5501/11.
Critical
1 Location of cartridge retainer X-ray
2 Gap between cartridge retainer and chamber X-ray
3 Gap between firing pin housing and cap X-ray
4 Foreign matter in gas port Visual
Major
101Length from cap boss face to gas port face, max Gage
102Protrusion of firing pin, max Gage
103Set screw missing, loose, or above flush Manual/Visual
Minor
None defined
4.2.2.5 Assembly, Drawing 8596101.
6