MIL-DTL-60286C
Major
101
Set screw missing or insecure
Visual
102
Burr
Visual
103
Foreign matter
Visual
Minor
201
Thread sealing compound missing from setscrews
Visual
202
Protective cap or plug missing
Visual
203
Protective finish inadequate or defective
Visual
4.2.3 Inspection testing. The following tests shall be performed in accordance with 4.3.
4.2.3.1 Breakaway torque. Each assembly shall be subjected to the breakaway torque test of the
threaded joint between the cap and the chamber. Failure of any assembly to comply with 3.3 shall be
cause for rejection of the assembly.
4.2.3.2 Residual magnetism. Each initiator shall be subjected to the test for excessive residual
magnetism as specified in 4.3.2. Failure of any initiator to comply with 3.4 shall be cause for rejection of
the initiator.
4.2.3.3 Functional tests. The following tests shall be performed by the Government.
4.2.3.3.1 Ballistics. Twenty-one units shall be tested to determine compliance with 3.6. The units shall
be temperature conditioned as provided in table II and 4.3.3.2. Failure of any unit to comply with 3.6
shall be cause for rejection of the lot.
TABLE II. Conditioning temperature.
Temperature (bF)
Sample Size
-60 to -70
7
65 to 75
7
195 to 205
7
4.2.3.3.2 Retest. There shall be no retests.
4.2.3.3.3 Test failure. If a test failure is attributable to an assignable cause, excluding the test initiator,
the original test results shall be discarded and that test reconducted.
4.3 Test methods and procedures.
7