MIL-DTL-60286C
Major
101
O-ring not lubricated
Visual
102
Burr
Visual
103
Foreign matter
Visual
Minor
None defined
4.2.2.3 Assembly, Drawing 10520619, less all drawings except Drawings 10520407, 10520414, and
8597230.
Characteristics
Defect
Method of Inspection
Critical
1
Cartridge not properly seated
Visual
2
Filter missing or insecure
Visual
3
Nylon patch missing or improperly applied
Visual
Major
101
Burr
Visual
102
Foreign matter
Visual
Minor
None defined
4.2.2.4 Assembly, Drawing 10520619.
Characteristics
Defect
Method of
Inspection
Critical
1
Cartridge face not seated against base of firing pin housing
Visual/X-ray
2
Any part missing
Visual/X-ray
3
Improper assembly
Visual/X-ray
4
Marking missing, incorrect, or illegible
Visual
6
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business