MIL-I-46576A(OS)
202 |
Box damaged |
Visual |
203 |
Sealing strip broken or missing |
Visual |
204 |
Marking missing, incorrect, or illegible |
Visual |
205 |
Cut, damaged, or improperly sealed bag |
Visual |
4.2.2.7 Box, Ammunition, Packing, Drawing 8796542.
Critical None defined |
||
Major None defined |
||
Minor 201 |
Contents loose |
Manual |
202 |
Strapping missing, loose, broken, or improperly engaged |
Visual/Manual |
203 |
Contents of box exposed |
Visual |
204 |
Box damaged |
Visual |
205 |
Marking missing, incorrect, or illegible |
Visual |
206 |
Number of units incorrect |
Visual |
4.2.2.8 Box, Fiberboard (Outer), Alternative, Ammunition, Packing, Drawing 9216934.
Critical None defined |
||
Major None defined |
||
Minor 201 |
Contents loose |
Manual/Visual |
202 |
Carton broken or damaged |
Visual |
203 |
Number of units contained incorrect |
Visual |
204 |
Marking missing, incorrect, or illegible |
Visual |
205 |
Tape incomplete |
Visual |
4.2.3 Inspection testing. The following tests shall be performed in accordance with 4.3.
4.2.3.1 Breakaway torque. Each assembly shall be subjected to the breakaway torque test of the threaded joint between the cap and the chamber. Failure of any assembly to comply with 3.3 shall be cause for rejection of the assembly.
4.2.3.2 Residual magnetism. Each initiator shall be subjected to the test for excessive residual magnetism as specified in 4.3.2. Failure of any initiator to comply with 3.4 shall be cause for rejection of the initiator.
7