MIL-DTL-82763B
Inspection conditioning. Unless otherwise specified (see 6.2), all inspections shall be performed
4.2
under the following conditions:
a.
Temperature: Room ambient 20 to 25 °C (68 to 77 °F)
b.
Altitude: Normal ground
c.
Humidity: 50 percent relative, maximum
d.
Atmospheric pressure: 14.7 psia.
Quality conformance inspection.
4.3
Lot.
4.3.1
4.3.1.1 Submission of product. The product shall be submitted in accordance with ASQ Z1.4.
4.3.1.2 Size of lot. For the purpose of identification and shipment, the shipping lots of metal parts
assemblies shall consist of 1200 assemblies, maximum, provided the homogeneity requirements of
inspection lots have been retained.
4.3.2 Examination. Of reprocessed parts 100 percent examination shall be performed for all critical
defects. Examination for major and minor defects shall be performed on a defect basis in accordance with
the classification of defects contained herein. Four power (4X) magnification may be used in performing
visual examination for such defects as burr and foreign matter. Inspection for rubber O-rings shall be in
accordance with ISO 3601-3. When compliance with the applicable requirements is in doubt as a result
of visual examination, the characteristic shall be measured or gaged to determine acceptability. All
nonconforming material shall be rejected.
4.3.2.1 Examination of reclaimed parts. Examination of reuseable parts, which require no reprocessing
shall be limited to inspection of defects that require visual type inspection. One hundred percent
examination shall be performed for all such defects. All nonconforming parts shall be reprocessed or
rejected.
4.3.2.2 Chamber, Initiator, Drawing 10520407, covering a detail of Drawing 10520551.
Characteristic
Defect
Method of Inspection
Critical
None Defined
Major
101
Pitch diameter of large external thread, min
Gage
102
Major diameter of large external thread, min
Gage
103
Pitch diameter of small external thread, min
Gage
104
Major diameter of small external thread, min
Gage
105
Pitch diameter of internal thread, max
Gage
106
Minor diameter of internal thread, max
Gage
107
Thread damage
Visual
108
Metal defective
Visual
109
Protective finish, inadequate or defective
Visual
110
Surface finish of cavity and angle of gas port,
Visual
improper
111
Burr
Visual
112
Foreign matter present
Visual