MIL-DTL-82763B
Hydrostatic pressure. The initiator chamber and cap shall withstand a hydrostatic pressure of
3.2
14,000 to 15,000 pounds per square inch (psi) for 15 seconds, minimum, without deformation or
mechanical failure (see 6.3.1).
Firing pin release. The firing pin of the metal parts assembly, less safety pin, shall release from
3.3
the cocked position when the application of an axial load of 15 to 30 pounds has withdrawn the initiator
pin 0.370 inch, minimum, and 0.425 inch, maximum.
Initiator pin security. Application of an axial load of 200 to 220 pounds to the initiator pin of
3.4
the metal parts assembly shall not withdraw the initiator pin past the safety pin. Load application shall
cause no permanent deformation of the safety pin.
Protective finish. Protective finish shall be in accordance with the applicable specifications and
3.5
drawings and shall apply to all surfaces of the component, regardless of configuration. Remanufactured
exterior components shall have the existing protective finish stripped and the specified protective finish
reapplied (see 6.6).
Residual magnetism. The metal parts assembly shall not deflect the indicator of the compass
3.6
more than five degrees in either direction using procedures in 4.6.5 (see 6.5).
Metal parts assembly. Parts shall be combined to produce an assembly, which conforms to the
3.7
requirements of the metals parts assembly drawing. All threaded joints shall be assembled hand tight (see
6.5).
Workmanship. The requirements for workmanship are as specified on the applicable drawings,
3.8
referenced specifications, and the following (see 6.6):
3.8.1 Metal defects. All components shall be free from cracks, splits, cold shuts, inclusions, porosity,
or any similar defect.
3.8.2 Burr. No part shall have a burr which might interfere with the assembly or function of the item
or which might be injurious to personnel handling the item.
3.8.3 Foreign matter. No part or assembly shall contain chips, dirt, grease, rust, corrosion, or other
foreign matter.
4. VERIFICATION
Classification of inspections. The inspection requirements specified herein are classified as
4.1
follows:
a. Conformance inspection.
4.1.1 Quality assurance terms and definitions. Reference shall be made to ASQ A8402 to define the
quality assurance terms used.
Inspection. Inspection shall be in accordance with MIL-A-2550.
4.1.2
3
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business