MIL-DTL-60277B
4.2.2.8 Box, Ammunition Packing, Drawing 8796827.
Characteristic
Defect
Method of Inspection
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual
202
Strapping missing, loose, broken, or improperly engaged Visual/Manual
203
Contents of box exposed
Visual
204
Box damaged
Visual
205
Marking missing, incorrect, or illegible
Visual
206
Number of units incorrect
Visual
4.2.2.9 Box, Fiberboard (Outer) Alternative Ammunition Packing, Drawing 9216824.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual/Visual
202
Carton broken or damaged
Visual
203
Number of units contained incorrect
Visual
204
Marking missing, incorrect, or illegible
Visual
205
Tape incomplete
Visual
4.2.3 Inspection testing. The following tests shall be performed in accordance with the provisions of 4.3.
4.2.3.1 Breakaway torque. Each assembly shall be subjected to the breakaway torque test of the
threaded joint between the cap and the chamber. Failure of any assembly to comply with the requirements
of 3.3 shall be cause for rejection of the assembly.
4.2.3.2 Residual magnetism. Each initiator shall be subjected to the test for excessive residual
magnetism as specified in 4.3.2. Failure of any initiator to comply with the requirement of 3.4 shall be
cause for rejection of the initiator.
4.2.3.3 Functional tests. The following tests shall be performed by the Government.
4.2.3.3.1 Ballistics. Twenty-one units shall be tested to determine compliance with the requirements of
3.5. The units shall be temperature conditioned as provided in table II and 4.3.3.2. Failure of any unit to
comply with the requirements of 3.5 shall be cause for rejection of the lot.
4.2.3.3.2 Retest. There shall be no retests.
8
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business