MIL-DTL-60277B
Characteristic
Defect
Method of Inspection
Minor
None defined
4.2.2.5 Assembly, Drawing 8597941, less specifications MIL-C-5501/10 and MIL-C-5501/11.
Critical
1
Cartridge retainer position improper
Gage
2
Foreign matter in gas port
Visual
Major
101
Length from cap boss face to gas port face, max
Gage
102
Set screw missing, loose or above flush
Visual/Manual
Minor
None defined
4.2.2.6 Assembly, Drawing 8597941.
Critical
1
Base of firing pin housing not in complete contact
With face of cartridge
Manual/X-ray
2
Any part missing, except as otherwise classified
Visual/X-ray
3
Improper assembly
Visual/X-ray
4
Marking missing, Incorrect, or Illegible
Visual
Major
101
Height of cap, max
Gage
102
Set screw not covered with barrier material
Visual
Minor
201
Total length, max
Measure
.
202
Location of labels Incorrect
Visual
203
Protective cap or plug missing
Visual
204
Protective finish inadequate or defective
Visual
4.2.2.7 Box, Fiberboard (Inner) Ammunition, Drawing 8796826.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual
202
Box damaged
Visual
203
Sealing strip broken or missing
Visual
204
Marking missing, incorrect, or illegible
Visual
205
Cut, damaged, or improperly sealed bag
Visual