MIL-DTL-50713B
4.3.2.1 Examination of reclaimed parts. Examination of reusable parts, which require no
reprocessing, shall be limited to inspection of defects that require visual type inspection. One hundred
percent examination shall be performed for all such defects. All nonconforming parts shall be reprocessed or
rejected.
4.3.2.2 Piston, Drawing 10534181, covering a detail of Drawing 11730535.
Characteristics
Defect
Method of Inspection
Critical
None defined
Major
101
Threads damaged or not full
Visual
102
Metal defective
Visual
103
Protective finish inadequate or defective
Visual
104
Burr or sharp corner
Visual
105
Foreign matter
Visual
Minor
201
Depth of threaded holes
Gage
202
Radius or chamfer incorrect
Gage
203
Radius or chamfer missing
Visual
204
Surface finish improper
Visual
4.3.2.3 Body Assembly, Drawing 10534179, covering a detail of Drawing 11730535.
Critical
None defined
Major
101
Metal defective
Visual
102
Protective finish inadequate or defective
Visual
103
Burr or sharp corner
Visual
104
True position of slots
Gage
105
Symmetry of slots with each other and with body datum
diameter
Gage
106
Depth of slots
Gage
107
Width of slots
Gage
108
Deleted
Minor
201
Radius or chamfer incorrect
Visual
202
Surface finish improper, except as otherwise classified
Visual
5