MIL-DTL-50713B
205
Marking missing, incorrect, or illegible
Visual
206
Number of units incorrect
Visual
4.3.2.18 Box, Fiberboard (Outer), Alternative, Packing, Ammunition, Drawing 9217579.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual/Visual
202
Hardware missing, loose, broken, or
improperly engaged
Visual
203
Strapping missing, loosed, broken, or
improperly engaged
Visual
204
Contents of box exposed
Visual
205
Box damaged
Visual
206
Marking missing, incorrect, or illegible
Visual
4.4 Inspection testing. The following tests shall be performed in accordance with 4.5.
4.4.1 Hydrostatic pressure. Each body and head shall be subjected to the hydrostatic pressure test.
Failure of any unit to comply with 3.2 shall be cause for rejection of the subassembly.
4.4.2 Structural strength. Each thruster shall be subjected to the structural strength test. Failure of
any thruster to comply with the requirements of 3.3 shall be cause for rejection of the thruster.
4.4.3 Protective finish. The number of units for protective finish tests shall be in accordance with the
applicable specification. Failure of any unit in the inspection sample to comply with the requirements of the
applicable specification shall be cause for rejection of the lot.
4.4.4 Residual magnetism. Each assembly shall be subjected to the test for excessive residual
magnetism as specified in 4.5.4. Failure of any unit in the inspection sample to comply with 3.5 shall be
cause for rejection of the assembly.
4.4.5 Shear pin strength. Fifty pins from each lot of shear pins shall be tested for shear strength.
Failure of any shear pin to comply with 3.6 shall be cause for rejection of the lot.
4.5 Test methods and procedures.
4.5.1 Hydrostatic pressure. Prior to application of protective finish the body and head shall be
mounted in a device, using a fixture for properly sealing all openings, and subjected to the internal
hydrostatic pressure to determine compliance with 3.2.
11