MIL-T-60696A(OS)
(Unless otherwise indicated, copies of federal and military specifications and standards are available from
Standardization Documents Order Desk, Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.)
2.1.2 Other Government documents, drawings, and publications. The following Government
drawings form a part of this specification to the extent specified herein. Unless otherwise specified, the issues
are those cited in the solicitation (see 6.2).
DRAWINGS
Naval Surface Warfare Center, Indian Head (CAGE Codes 19200 and 19203)
8593874
Thruster, Cartridge Actuated, M2A2, Metal Parts Assembly
8797633
Box, Fiberboard (Inner), Packing, Ammunition, For Thruster, Cartridge Actuated,
M2A2
8797637
Box, Packing, Ammunition, For Thruster, Cartridge Actuated, M2A2
9235819
Box, Fiberboard (Outer), Alternative, Packing Ammunition, for Thruster, Cartridge
Actuated, M2A2
U.S. Air Force
TPO 00-921-5048
Thruster, Cartridge Actuated, M2A2
(Application for copies should be addressed to: Commander, Indian Head Division, Naval Surface Warfare
Center, Attn: Data Control Branch (Code 8410), Indian Head, MD 20640-5035.)
2.2 Order of precedence. In the event of a conflict between the text of this document and the references
cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes
applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Materials. All materials used in the manufacture of the thrusters shall conform to the specifications
referred to on the respective drawings unless specific approval in writing covering a departure therefrom has
been obtained from the cognizant Navy design activity prior to manufacture. When alternate materials or
methods of manufacture are specified on the drawings, the bidder's selections shall be clearly stated in the
proposal. The remanufactured thruster metal parts assembly shall contain the following new parts: shear pin,
O-rings, piston locking spring, setscrews, cap screws, and snap ring.
3.2 Hydrostatic pressure. The body and head shall withstand a hydrostatic pressure of 10,000 pounds
per square inch (psi) for 15 seconds, minimum, without leaking, deformation, or mechanical failure (see 6.3.1).
2