MIL-T-60694B
2.1.2 Other Government documents, drawings, and publications. The following Government
drawings form a part of this specification to the extent specified herein. Unless otherwise specified, the issues
are those cited in the solicitation (see 6.2).
DRAWINGS
Naval Surface Warfare Center, Indian Head (CAGE Codes 19200 and 19203)
10520876
Thruster, Cartridge Actuated, M15, Metal Parts Assembly
8858440
Box, Packing, Ammunition, For Thruster, Cartridge Actuated, M15
8858441
Box, Fiberboard (Inner), Packing, Ammunition, For Thruster, Cartridge Actuated,
M15
9217560
Box, Fiberboard (Outer), Alternative, Packing Ammunition, for Thruster, Cartridge
Actuated, M15
U.S. Air Force
TPO 00-607-0314
Thruster, Cartridge Actuated, M15
(Application for copies should be addressed to: Commander, Indian Head Division, Naval Surface Warfare
Center, Attn: Data Control Branch (Code 8410), Indian Head, MD 20640-5035.)
2.2 Order of precedence. In the event of a conflict between the text of this document and the references
cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes
applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Materials. All materials used in the manufacture of the thrusters shall conform to the specifications
referred to on the respective drawings unless specific approval in writing covering a departure therefrom has
been obtained from the cognizant Navy design activity prior to manufacture. When alternate materials or
methods of manufacture are specified on the drawings, the bidder's selections shall be clearly stated in the
proposal. The remanufactured thruster metal parts assembly shall contain the following new parts or items:
shear pins, gasket, silicone fluid, O-rings, leather backup rings, and retainer rings.
3.2 Hydrostatic pressure. The body shall withstand a hydrostatic pressure of 11,000 pounds per square
inch (psi) for 15 seconds, minimum, without leaking, deformation, or mechanical failure (see 6.3.1).
3.3 Protective finish. Protective finish shall be in accordance with the applicable specifications and
drawings and shall apply to all surfaces of the component regardless of configuration. Remanufactured
exterior components (see 6.3.2) shall have the existing protective finish stripped and the specified protective
finish reapplied. When there are only small surface areas of exposed base metal on the aluminum exterior
2
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business