MIL-T-46605B
4.5.1 Lot.
4.5.1.1 Submission of product. Unless otherwise specified by the contracting activity, formation and identification of lots shall be in accordance with MIL-STD-105.
4.5.1.2 Size of lot. The production lot size shall be as specified in the contract.
4.5.2 Examination. One hundred percent examination shall be performed for all critical defects. Examination for major and minor defects shall be performed on a defect basis in accordance with the classification of defects. Four power (4x) magnification may be used in performing visual examination for such defects as burr and foreign matter. Inspection for rubber O-rings shall be in accordance with MIL-STD-
413. When compliance with the applicable requirement is in doubt as a result of visual examination, the
characteristic shall be measured or gaged to determine acceptability. All nonconforming material shall be rejected.
4.5.2.1 Pin, Shear, Firing Pin, Drawing 10520486, covering a detail of Drawing 10520974.
Characteristics Critical |
Defect |
Method of Inspection |
None defined |
||
Major 101 |
Diameter, max |
Gage |
102 |
Total length, min |
Gage |
103 |
Metal defective |
Visual |
104 |
Protective finish inadequate or defective |
Visual |
105 |
Burr or sharp corner |
Visual |
106 |
Foreign matter |
Visual |
Minor 201 |
Total length, max |
Gage |
202 |
Surface finish improper |
Visual |
4.5.2.2 Pin, Shear, Piston, Drawing 10520487, covering a detail of Drawing 10520974.
Critical
None defined
Major
101 Diameter, max Gage
102 Total length, min Gage
5
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business