MIL-T-46590C
Minor |
||
201 |
Contents loose |
Visual/Manual |
202 |
Strapping missing, loose, broken, or improperly assembled |
Visual/Manual |
203 |
Contents of box exposed |
Visual |
204 |
Box damaged |
Visual |
205 |
Marking missing, incorrect, or illegible |
Visual |
206 |
Number of units incorrect |
Visual |
4.5.2.28 Box, Fiberboard (Outer), Alternative, Packing, Ammunition, Drawing 9217560.
Critical None defined |
||
Major None defined |
||
Minor 201 |
Contents loose |
Manual/Visual |
202 |
Carton broken or damaged |
Visual |
203 |
Number of units incorrect |
Visual |
204 |
Marking missing, incorrect, or illegible |
Visual |
205 |
Tape incomplete |
Visual |
4.5.3 Inspection testing. The following tests shall be performed in accordance with 4.6.
4.5.3.1 Hardness. Fifty units from each heat treated lot of components shall be tested for compliance with the requirements on the applicable drawing. Failure of any unit to comply with the drawing requirements shall be cause for rejection of the lot of components.
4.5.3.2 Hydrostatic pressure. Each body shall be subjected to the hydrostatic pressure test. Failure of any cap or chamber subassembly to comply with 3.4 shall be cause for rejection of the subassembly.
4.5.3.3 Shear pin strength. Fifty pins of each type from each lot of shear pins shall be tested for shear strength. Failure of any shear pin to comply with 3.5 shall be cause for rejection of the lot.
4.5.3.4 Protective finish. The number of units for protective finish tests shall be in accordance with the applicable specification. Failure of any unit in the inspection sample to comply with the requirements of the applicable specification shall be cause for rejection of the lot.
4.5.3.5 Residual magnetism. Each assembly shall be subjected to the test for excessive residual magnetism as specified in 4.6.7. Failure of any unit in the inspection sample to comply with 3.9 shall be cause for rejection of the assembly.
4.5.3.6 Welding.
4.5.3.6.1 Reservoir assembly. The welding procedure and the welding equipment shall be subjected to tests for consideration of approval. The welding operator shall be subjected to a qualification test. Failure
22