MIL-I-602848
205Cut, damaged, or improperly sealed bag Visual
4.2.2.7 Box, Ammunition Packing, Drawing 8798142.
Critical
None defined
Major
None defined
Minor
201Contents looseManual
202Strapping missing, loose, broken, or improperly engaged Visual/Manual
203Contents of box exposed Visual
2048ox damaged Visual
205Marking missing, incorrect, or illegible Visual
206Number of units incorrect Visual
4.2.2.8 Box, Fiberboard (Outer) Alternative Ammunition Packing, Drawing 9216933.
Critical
None defined
Major
None defined
Minor
201Contents looseManual/Visual
202Carton broken or damageVdisual
203Number of units contained incorrect Visual
204Marking missing, incorrect, or illegible Visual
205Tape incomplete Visual
4.2.3 Inspection testing. The following tests shall be performed in accordance with 4.3.
4.2.3.1 Breakawaytorque. Eachassemblyshallbesubjectedtothebreakawaytorquetestof thethreadedjointbetweenthecapandthechamber. Failureofanyassemblytocomplywith3.3 shall be cause for rejection of the assembly.
4.2.3.2 Residual magnetism. Each initiator shall be subjected to the test for excessive residual magnetism as specified in 4.3.2. Failure of any initiator to comply with 3.4 shall be cause for rejection of the initiator.
4.2.3.3 Firing pin release. The initiator pin of each subassembly shall be subjected to the firing pin release test. Failure of any subassembly to comply with the requirements of 3.5 shall be cause for rejection of the subassembly.