MIL-DTL-60525B
None defined
Minor
201
Contents loose
Manual
202
Strapping missing, loose, broken, or improperly
Manual/Visual
assembled
203
Contents of box exposed
Visual
204
Box damaged
Visual
205
Marking missing, incorrect, or illegible
Visual
206
Number of units incorrect
Visual
4.5.2.14 Box, Fiberboard (Outer) Alternative, Packing, Ammunition, Drawing 9241155
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual
202
Box broken or damaged
Visual
203
Number of units contained incorrect
Visual
204
Marking missing, incorrect, or illegible
Visual
205
Tape incomplete
Visual
4.5.3 Inspection testing. The following tests shall be performed in accordance with the provisions
of 4.6.
4.5.3.1 Hardness. Fifty units from each heat treated lot of components shall be tested for
compliance with the requirements on the applicable drawing. Failure of any unit to comply with
the drawing requirements shall be cause for rejection of the lot of components.
4.5.3.2 Hydrostatic pressure. Each chamber and cap subassembly shall be subjected to the
hydrostatic pressure test. Failure of any cap or chamber subassembly to comply with the
requirement of 3.4 shall be cause for rejection of the subassembly.
4.5.3.3 Firing pin release. The initiator pin of each partial assembly consisting of all parts, except
the safety pin and chamber, shall be subjected to the firing pin release test. Failure of any partial
assembly to comply with the requirement of 3.5 shall be cause for rejection of the subassembly.
4.5.3.4 Initiator pin security. The initiator pin of each subassembly consisting of all parts, except
the chamber, shall be subjected to the initiator pin security test. Failure of any partial assembly to
comply with the requirement of 3.6 shall be cause for rejection of the subassembly.
14