MIL-DTL-60517C
4.5.2.13 Box, Ammunition, Packing, Drawing 8830985.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual
202
Strapping missing, loose, broken, or
Manual/Visual
improperly assembled
203
Contents of box exposed
Visual
204
Box damaged
Visual
205
Marking missing, incorrect or illegible
Visual
206
Number of units incorrect
Visual
4.5.2.14 Box, Fiberboard (Outer) Alternative, Ammunition Packing, Drawing 9241155.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual
202
Box broken or damaged
Visual
203
Number of units contained incorrect
Visual
204
Marking missing, incorrect or illegible
Visual
205
Tape incomplete
Visual
Inspection testing. The following tests shall be performed in accordance with the provision of
4.5.3
4.6.
4.5.3.1 Hardness. Fifty units from each heat-treated lot of components shall be tested for compliance
with the requirements on the applicable drawing. Failure of any unit to comply with the drawing
requirements shall be cause for rejection of the lot of components.
4.5.3.2 Hydrostatic pressure. Each chamber and cap shall be subjected to the hydrostatic pressure test.
Failure of any cap or chamber subassembly to comply with the requirements of 3.4 shall be cause for
rejection of the subassembly.
4.5.3.3 Firing pin release. The initiator pin of each partial assembly, consisting of all parts except the
safety pin, cartridge and chamber, shall be subjected to the firing-pin release test. Failure of any partial
assembly to comply with the requirements of 3.5 shall be cause for rejection of the subassembly.
4.5.3.4 Initiator pin security. The initiator pin of each subassembly, consisting of all parts except the
chamber, shall be subjected to the initiator pin security test. Failure of any subassembly to comply with
the requirements of 3.6 shall be cause for rejection of the subassembly.
4.5.3.5 Protective finish. The number of units for protective finish tests shall be in accordance with the
applicable specification. Failure of any unit in the inspection sample to comply with the requirements of
the applicable specification shall be cause for rejection of the lot.