MIL-DTL-50374B
4.2.2.3 Box, Ammunition Packing, Drawing 9252248.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual
202
Strapping missing, loose, broken, or improperly engaged
Visual/Manual
203
Contents of box exposed
Visual
204
Box damaged
Visual
205
Marking missing, incorrect, or illegible
Visual
206
Number of units incorrect
Visual
4.2.2.4 Carton, Alternative, Ammunition Packing, Drawing 9252249.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual/Visual
202
Carton broken or damaged
Visual
203
Number of units contained incorrect
Visual
204
Marking missing, incorrect, or illegible
Visual
205
Tape incomplete
Visual
4.2.3 Inspection testing. The following tests shall be performed in accordance with 4.3.
4.2.3.1 Breakaway torque. Each assembly shall be subjected to the breakaway torque application.
Failure of any assembly to comply with 3.4 shall be cause for rejection of the assembly.
4.2.3.2 Residual magnetism. Each initiator shall be subjected to the test for excessive residual
magnetism as specified in 4.3.2. Failure of any initiator to comply with 3.5 shall be cause for rejection of
the initiator.
4.2.3.3 Functional tests. The following tests shall be performed by the Government.
4.2.3.3.1 Ballistics. Twenty-one units shall be tested to determine compliance with 3.8. The units
shall be temperature conditioned as provided in table II and 4.3.5.2. Failure of any unit to comply with 3.8
shall be cause for rejection of the lot.