MIL-DTL-46618C (OS)
DOT Marking - Explosive Power Device - Class C - Handle Carefully - Keep Fire Away
6.5 Packing and marking. Packing and marking should be Level A or B, as specified by the contracting
activity (see 6.2). Level A should be in accordance with Drawings 8797373 and 8797441. Level B should
be in accordance with Drawings 8797373 and 9225380.
6.6 Hazard notice. The cartridge described herein and certain of its components are flammable or
explosive and present hazards in manufacture, handling, storage, and shipment. The contractor should
recognize these properties and take appropriate measures to guard and protect against fire, explosion,
adverse environment, corrosive atmosphere, rough handling, and electrically induced incidents.
6.7 Definitions.
6.7.1 Ignition delay. Ignition delay is the time between the firing pin striking the Ignition Device or
ignition device and the first indication of pressure in the closed bomb. ,
6.7.2 Time to Pmax. Time to Pmax is the time that elapses between the beginning of a continuous
pressure rise and the point of maximum pressure on the pressure versus time record.
6.8 Subject term (keyword) listing.
Ejection systems, aircrew
Emergency escape systems, aircrew
Escape systems, aircrew
Life-saving systems, aircrew
6.9 Changes from previous issue. Marginal notations are not used to identify changes with respect to the
previous issue because of the extensiveness of the changes.
Custodian:
Preparing activity:
Navy - OS
Navy - OS
(Project 1377-2011-005)
NOTE: The activities listed above were interested in this document as of the date of this document. Since
organizations and responsibilities can change, you should verify the currency of the information above
using the ASSIST Online database at https://assist.daps.dla.mil.