MIL-DTL-23659F
3.4.3. Maximum No-Fire and Minimum 50 Millisecond All-Fire Stimuli.
3.4.3.1. General. For purposes of specifying maximum no-fire and minimum 50
millisecond all fire stimuli, initiators covered by this specification are divided into two Classes:
"Class A" and "Class B".
3.4.3.1.1. Class A. Includes any initiator that is capable of being actuated within one
second (exclusive of delay element time, if present) from a 28 ± 2 volt source capable of
delivering not less than 10 amperes.
3.4.3.1.2. Class B. Includes any initiator that is not capable of being actuated within
one second (exclusive of delay element time, if present) from a 28 ± 2 volt DC source capable
of delivering not less than 10 amperes.
3.4.3.2. Maximum No-Fire Stimuli, Class A
3.4.3.2.1. Power-Current. The initiator shall not fire within 5 minutes when subjected to
a current of 1 ampere minimum per bridge with an associated power of 1 watt minimum per
bridge. The initiator shall meet this requirement at 70° ± 5°F and 220° ± 5°F. The test method
shall be as explained in 4.4.3.1.
3.4.3.2.2. Static Discharge. The initiator shall not fire or dud when subjected to the
25000 volt simulated human electrostatic discharge of 4.4.3.2. The initiator shall meet this
requirement at 70° ± 5°F and a relative humidity of 50 percent or less.
3.4.3.2.3. Stray Voltage. The initiator shall be capable of withstanding the effects of a
stray voltage environment without pre-igniting (firing). The initiator shall meet this requirement
at 70° ± 5°F. The test method shall be as described in 4.4.3.3.
3.4.3.3. Minimum 50 Milliseconds All-Fire Stimulus, Class A. The minimum 50
millisecond all-fire stimulus as defined in 6.3.7 shall be measured as described in 4.4.4. The
initiator shall meet this requirement at 70° ± 5°F, - 80° ±5°F, and 225° ± 5°F.
3.4.3.4. Maximum No-Fire Stimuli, Class B.
3.4.3.4.1. Parameter(s). The maximum no-fire stimulus as defined in paragraph 6.3.9
shall be determined as specified in paragraph 4.4.5.1.
3.4.3.4.2. Static Discharge. The initiator shall not fire or dud when subjected to the
25000 volt simulated human electrostatic discharge of 4.4.3.2. The initiator shall meet this
requirement at 70° ± 5°F and a relative humidity of 50 percent or less.
3.4.3.5. Minimum 50 Millisecond All-Fire Stimuli, Class B. The requirements for the
minimum 50-millisecond all-fire stimulus as defined in 6.3.7 shall be as specified in 4.4.6.
3.4.4. Bridge Circuit Resistance Subsequent to Actuation Class A and B. If there is a
requirement that a fired initiator shall have a minimum open circuit resistance after firing, then
the cognizant Safety Authority shall specify the open circuit resistance requirement and the
method of test shall be that given in 4.5.