MIL-I-60518A
204 Cut, damaged, or improperly sealed bag Visual
4.5.2.9 Box, Packing, Ammunition, Drawing 8830993.
Critical None defined |
||
Major None defined |
||
Minor 201 |
Contents loose |
Visual/Manual |
202 |
Strapping missing, loose, broken, or improperly assembled |
Visual/Manual |
203 |
Contents of box exposed |
Visual |
204 |
Box damaged |
Visual |
205 |
Marking missing, incorrect, or illegible |
Visual |
206 |
Number of units incorrect |
Visual |
4.5.2.10 Box, Fiberboard (Outer), Alternative, Packing, Ammunition, Drawing 9216932.
Critical None defined |
||
Major None defined |
||
Minor 201 |
Contents loose |
Manual/Visual |
202 |
Carton broken or damaged |
Visual |
203 |
Number of units contained incorrect |
Visual |
204 |
Marking missing, incorrect, or illegible |
Visual |
205 |
Tape incomplete |
Visual |
4.5.3 Inspection testing. The following tests shall be performed in accordance with 4.6.
4.5.3.1 Hardness. Fifty units from each heat treated lot of components shall be tested for compliance with the requirements on the applicable drawing. Failure of any unit to comply with the drawing requirements shall be cause for rejection of the lot of components.
4.5.3.2 Hydrostatic pressure. Each chamber and cap shall be subjected to the hydrostatic pressure test. Failure of any cap or chamber subassembly to comply with 3.4 shall be cause for rejection of the subassembly.
4.5.3.3 Shear pin strength. Fifty pins from each lot of shear pins shall be tested for shear strength.
Failure of any shear pin to comply with 3.5 shall be cause for rejection of the lot.
11
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business