MIL-DTL-85097/2F
The best fit line to a set of n data points [X,Y] is defined as Y' = a+bX, where:
∑x ∑ y -∑x ∑ x y
2
a=
i
i
i
i
i
n∑ x - (∑ x )
2
2
i
i
n∑ xi yi - ∑ xi ∑ yi
b=
n∑ xi - (∑ xi ) 2
2
3.4.3 Chamber pressure. Combustion chamber pressure versus time shall be recorded for preproduction
units only.
TABLE II. Alternate ballistic performance requirements.
-65 ± 5 ° F
-65 ± 5 ° F
165 ± 5 ° F
165 ± 5 ° F
Parameters
Minimum
Maximum
Minimum
Maximum
Ignition delay (ms)
-
18
-
12
Initiation pressure (psig)
400
650
400
650
Maximum thrust (lb)
215
350
230
421
Burn time (ms)
230
350
190
250