MIL-DTL-50700A
Table I. First article samples and tests.
Paragraphs
Type of test
Test
Sample size
Requirement
Test
Destr
Non-Destr
3.2
4.4.1
Shear Pin Strength
50
X
--
In quantities set up in applicable
X
3.3
4.4.2
Protective Finish
--
specification
Dwg.
4.4.3
Hardness
50
X
--
3.4
4.4.4
Residual Magnetism
each
--
X
The sample shall be manufactured using the same materials, equipment, processes and procedures as used
in regular production. All parts and materials, including packaging shall be the same as used in regular
production and shall be obtained from the same source of supply.
4.2.1.1 Examination and tests. After examination and provisional acceptance at source, the sample shall
be inspected for all requirements of the drawings and specifications at a Government laboratory or such
other facility specified in the contract.
4.2.1.2 Initial production failure. Failure of the sample to comply with the requirements of the drawings
and specifications shall result in sample disapproval.
4.3 Inspection provisions.
4.3.1 Lot.
4.3.1.1 Submission of product. The product shall be submitted in accordance with ANSI/ASQ Z1.4.
4.3.1.2 Size of lot. A lot shall consist of an identifiable group of metal parts assemblies consisting of
components produced by a homogeneous process.
4.3.2 Examination. One hundred percent examination shall be performed for all critical defects.
Examination for major and minor defects shall be performed on a defect basis in accordance with the
classification of defects contained herein, using the sampling plans and associated criteria in Tables II and
III. For an individual defect (single characteristic), the criteria in Table II shall be used. For total defects
within a major or minor group the criteria in Table III shall be used. All non-conforming material shall be
rejected. Inspection for rubber O-rings shall be in accordance with MIL-STD-413. The surface roughness
comparison specimens prescribed in ASME B46.1-2002 shall be used as a basis of comparison for surface
roughness determination. Four power (4×) magnification may be used in performing visual examination
for such defects as burr and foreign matter.
Table II. Sample size and acceptance, individual defect.
Major
Major
Lot Size
Sample Size
Accept
Reject
Accept
Reject
1 -- 300
100% Examination
--
--
--
--
301 -- 1300
110
1
2
2
3
1301 -- 3200
150
2
3
3
4
3201 -- 8000
225
3
4
4
5
8001 -- 22000
300
4
5
5
6
4