MIL-C-60570B
Major
None defined
Minor
201
Contents loose
Manual/Visual
202
Separator or filler missing
Visual
203
Heat sealer incomplete, loose, or distorted
Visual
204
Cut or damaged through impregnated box
Visual
205
Marking missing, incorrect, or illegible
Visual
4.6.5 Box, Packing, ammunition, Drawing 8845191.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual
202
Strapping missing, loose, broken, or improperly assembled Visual
203
Contents of box exposed
Visual
204
Box damaged
Visual
205
Marking missing, incorrect, or illegible
Visual
206
Number of cartons incorrect
Visual
4.6.6 Carton, Alternative, Packing, Drawing 9227731.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual
202
Box broken or damaged
Visual
203
Number of units contained incorrect
Visual
204
Marking missing, incorrect, or illegible
Visual
205
Tape incomplete
Visual
4.7 Test methods and procedures.
4.7.1 Primer x-ray. Prior to assembly into the cartridge, the primer shall be radiographically examined
in accordance with MIL-STD-453. Each primer shall be x-rayed on boards or trays with the cup side
perpendicular to the rays. The x-ray negatives shall be identified by item nomenclature and by lot number.