MIL-C-46274C
66 to 110
10
111 to 180
15
181 to 300
25
301 to 500
30
501 to 800
35
801 to 1300
40
Over 1300
50
4.4.3 Temperature conditioning for ballistic test. The sample shall be temperature conditioned and
tested to determine compliance with 3.6.2.2. The sample for firing shall be conditioned to table II.
TABLE II. Temperature conditioning.
Temperature (·F)
Not vibrated
Vibrated
-60 to -70
3
4
65 to 75
3
4
195 to 205
3
4
4.4.4 First article failure. Failure of the sample to comply with the requirements of the drawings and
specifications shall result in first article sample disapproval.
4.5 Quality conformance inspection.
4.5.1 Lot.
4.5.1.1 Submission of product. The product shall be submitted in accordance with MIL-STD-105.
4.5.1.2 Lot size. The production lot size shall be as specified in the contract (see 6.2).
4.5.2 Examination and tests. The quality conformance sample shall be subjected to the examinations
of 4.6 and all the test procedures of 4.7 except for 4.7.7.
4.6 Examination. All cartridges and components shall be examined visually and radiographically and
characteristics defined in accordance with the applicable drawings. One hundred percent examination shall
be performed for all critical defects. Examination for major or minor defects shall be performed on a defect
basis in accordance with the classification of defects. Inspection for elastomeric O-rings shall be in
accordance with MIL-STD-413. Four power (4X) magnification may be used in performing visual
examination for such defects as burrs and foreign matter. When compliance is in doubt as a result of visual
inspection, the characteristic shall be measured or gaged to determine acceptability. All nonconforming items
shall be rejected.
6