MIL-C-46228B
4.8.1 Reconditioning. The sample must be tested within five minutes after removal from the
conditioning chamber. If this time is exceeded, the cartridge shall be reconditioned in accordance with 4.8.
4.9 Inspection of packaging. The sampling and inspection of the preservation, packing, and container
marking shall be in accordance with the requirements of section 5.
5. PACKAGING
5.1 Packing and marking. Packing and marking shall be Level A or B, as specified by the contracting
activity (see 6.2). Level A shall be in accordance with Drawings 8799620 and 8799621. Level B shall be in
accordance with Drawings 8799621 and 9224944.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful but is not
mandatory.)
6.1 Intended use. The assembly is used in cartridge actuated devices for Aircrew Emergency Escape
Systems.
6.2 Acquisition requirements. Acquisition documents must specify the following:
a.
Title, number, date, and revision letter of this specification
b.
Issue of DODISS to be cited in the solicitation and, if required, the specific issue of individual
documents referenced and that MIL-STD-810D shall be used (see 2.1, 3.5.3, and 4.7.7)
c.
Whether a first article sample is required (see 3.1, 4.4, and 6.3)
d.
Test facility for first article tests (see 4.4.1)
e.
Production test activity and lot size (see 4.1 and 4.5.1.2)
f.
Any special test conditions (see 4.3)
g.
Directions for sampling for classification of defects (see 4.6)
h.
Directions for shipping radiographs of primers and of entire lot of cartridge assemblies (see 4.7.1
and 4.7.4)
i.
Directions for sampling for protective finish tests (see 4.7.3)
j.
Level of preservation and packing (see 5.1)
k.
That the safety precaution requirements of the "Contractor's Safety Manual for Ammunition,
Explosives, and Related Dangerous Material," (DOD 4145.26M) are applicable. NOTE: When
12