MIL-C-46221B
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual/Visual
202
Strapping missing, loose, broken, or improperly assembled
Visual
203
Contents of box exposed
Visual
204
Box damaged
Visual
205
Marking missing, incorrect, or illegible
Visual
206
Number of cartons incorrect
Visual
4.6.12 Box, Fiberboard (Outer), Alternative, Drawing 9225381.
Critical
None defined
Major
None defined
Minor
201
Contents loose
Manual
202
Box broken or damaged
Visual
203
Number of units contained incorrect
Visual
204
Marking missing, incorrect, or illegible
Visual
205
Tape incomplete
Visual
4.7 Test methods and procedures.
4.7.1 Primer x-ray. Prior to assembly into the cartridge, the primer shall be radiographically examined
in accordance with MIL-STD-453. Each primer shall be x-rayed on boards or trays with the cup side
perpendicular to the rays. The x-ray negatives shall be identified by item nomenclature and by lot number.
Primers are to be left mounted to the boards or trays until after the x-rays have been reviewed and defects
identified to facilitate removal of defective units. After screening, the x-ray negatives with defectives
identified, shall be forwarded to the engineering activity designated by the acquiring activity. Interpretation
of the radiographic films shall verify the following:
Presence of Primer Charge
No Material Defects
4.7.2 Hardness. Ten units from each heat-treated lot of components shall be tested with a hardness tester.
Failure of any unit to comply with the requirements of the drawings shall be cause for rejection of the lot of
components.