MIL-DTL-23659F
c. Test specimens shall be supported on screen trays or racks so that all areas are exposed
to the prescribed atmospheric conditions at all times throughout the test.
Procedure:
Monday
0800
Place test items in a chamber maintained at +70°F at 50 percent relative
humidity (RH).
1200
Raise chamber temperature to + 160°F and the RH to 95 percent. The
chamber temperature shall reach + 160°F at 95 percent RH not later than
1360.
1600
Remove test items from above chamber and immediately place in a chamber
maintained at - 65°F at a pressure altitude of 70,000 feet. (0.65 psi)
Tuesday
0800
Remove test items from above chamber and immediately place in a chamber
maintained at + 70°F at 50 percent RH.
1200
Remove test items from above chamber and immediately place in a chamber
maintained at - 65°F at a pressure altitude of 70,000 feet. (0.65 psi)
1600
Remove test items from above chamber and immediately place in a chamber
maintained at + 160°F at 95 percent RH.
Wednesday 0800
Reduce chamber temperature to + 70°F at 50 percent RH. The chamber
temperature shall reach + 70°F at 50 percent RH not later than 0900.
1200
Raise chamber temperature to + 160°F at 95 percent RH. The chamber
temperature shall reach + 160°F at 95 percent RH not later than 1300.
1600
Remove test items from above chamber and immediately place in a chamber
maintained at - 65°F at a pressure altitude of 70,000 feet. (0.65 psi)
Thursday
0800
Remove test items from above chamber and immediately place in a chamber
maintained at + 70°F at 50 percent RH.
1200
Remove test items from above chamber and immediately place in a chamber
maintained at - 65°F at a pressure altitude of 70,000 feet. (0.65 psi)
0600
Remove test items from above chamber and immediately place in a chamber
maintained at + 160°F at 95 percent RH.
Friday
0800
Reduce chamber temperature to + 70°F at 50 percent RH. The chamber
temperature shall reach + 70°F at 50 percent RH not later than 0900.
1200
Raise chamber temperature to + 160°F at 95 percent RH. The chamber
temperature shall reach + 160°F at 95 percent RH not later than 1300.
1600
Remove the items from above chamber and immediately place in a chamber
maintained at - 65°F at standard ambient pressure.
d. This schedule shall be followed for a total of 4 weeks (28 days) except that on the
second and fourth weekends the soak time shall be from 1200 on Friday until 0800 on Monday at
a temperature of + 160°F at 95 percent RH. At the conclusion of the temperature-
shock/humidity/altitude test, the test items shall be allocated to the tests specified in Table I.
4.6.6. Cook-Off and High Temperature Exposure.
4.6.6.1. Cook-Off. Four initiators shall be placed in an oven preheated to the highest
temperature which it is estimated that the initiators will withstand for 1 hour. If no initiator